Thermo King · Cold treatment

USDA probe for Thermo King reefer containers

NTC pulp probes for cold treatment on Thermo King reefer containers. Configured for the USDA sensor setting of your controller, tested one by one and supplied with batch traceability.

Compatible replacement for Thermo King USDA sensors 41-8188 and 41-3107 (2.5 mm). See every equivalent part number in the USDA sensor cross-reference.

USDA probe with black PUR cable and stainless steel tip for Thermo King reefer containers
How it works

How Thermo King reefers record cold treatment

Thermo King reefer controllers, such as the MP-4000, accept three or four USDA sensors for cold treatment. The USDA Type setting in the controller configuration must match the sensor installed: Thermo King supports both NTC and PT100 style USDA sensors, each with its own setting.

01

Three or four USDA sensors

Setting the USDA type activates the spare sensor inputs used as USDA channels.

02

NTC or PT100

The controller must be set to the sensor style installed. Our USDA probes are NTC.

03

Data download

Cold-treatment events are recorded by the controller's datalogger and downloaded with Thermo King's LogView software.

Calibration

Calibrating USDA probes on Thermo King units

Thermo King calibrates USDA sensors in an ice bath of distilled water, using Calibrate Probes in the controller's Sensor menu. The display shows raw and corrected offsets. Offsets are accepted when every sensor reads within ±0.3 °C and stays stable for five minutes, and the sensors should be in the bath for at least 15 minutes in total.

Always follow the calibration procedure and acceptance limits in the manufacturer's documentation for your controller and software version.

Product

Our USDA probe for Thermo King

We confirm the controller, the USDA sensor setting and the connector for your Thermo King units before production, so every probe arrives ready to calibrate and use.

Sensing elementNTC thermistor
Probe bodySS316, 2.5 mm OD
Cable15 m PUR, black
VerificationEvery finished probe

Frequently asked questions

Which USDA type setting should I use with your probes?

Our probes are NTC sensors, so the controller must be set to the matching NTC USDA type. We confirm the exact setting for your controller and software version.

How many USDA sensors can a Thermo King reefer use?

Thermo King documentation refers to three or four USDA sensors. The protocol of each treatment defines how many are used and where they go in the load.

Why does the controller keep showing a correction during calibration?

Thermo King controllers show the correction until the sensor comes within ±0.3 °C of 0 °C. If several probes drift together, the bath itself is usually the cause: add ice, remove excess water and let it stabilize.

Need USDA probes for your Thermo King fleet?

Send us the reefer model, controller, quantity and destination market. We confirm the configuration and reply with pricing.

Reference price: USD 18 per probe (15 m cable).

USDA PROBE is an independent manufacturer and is not affiliated with or endorsed by the United States Department of Agriculture, Carrier Transicold, Thermo King, Maersk Container Industry (Star Cool) or Daikin. Brand names are used only to identify equipment platforms. Product suitability should be verified for each equipment model and treatment program.