Carrier · Cold treatment

USDA probe for Carrier Transicold reefer containers

NTC pulp probes for cold treatment on Carrier Transicold reefer containers. Built for the USDA channels recorded by the DataCORDER, tested one by one and supplied with batch traceability.

Compatible replacement for Carrier Transicold USDA sensors 12-50089-02 and 12-00789-20PK4 (NTC, 2.5 mm). See every equivalent part number in the USDA sensor cross-reference.

USDA probe with black PUR cable and stainless steel tip for Carrier Transicold reefer containers
How it works

How Carrier reefers record cold treatment

On Carrier Transicold units the USDA probe readings are recorded by the DataCORDER, the data recorder built into the MicroLink controller. Carrier's service documentation describes three remote USDA probes connected to the DataCORDER for cold treatment, each calibrated in an ice bath before use.

01

DataCORDER recording

USDA probe temperatures are logged with the trip data and downloaded with Carrier's DataLINE software.

02

MicroLink controllers

Carrier documents probe calibration for MicroLink controllers such as the ML2i and ML3.

03

Three USDA probes

Carrier documentation for cold treatment describes three remote USDA probes connected to the recorder.

Calibration

Calibrating USDA probes on Carrier units

On ML3 controllers Carrier offers an automatic calibration, in which the controller assumes the probes sit in a 0.0 °C ice bath, and an external method in which offsets between −0.3 °C and +0.3 °C are entered. On recent software a probe passes when its offset is within ±0.3 °C. Carrier's procedure calls for crushed ice made from distilled water, about 85 % ice, and a reference thermometer more accurate than the device being checked.

Always follow the calibration procedure and acceptance limits in the manufacturer's documentation for your controller and software version.

Product

Our USDA probe for Carrier

We confirm the controller, the USDA sensor setting and the connector for your Carrier units before production, so every probe arrives ready to calibrate and use.

Sensing elementNTC thermistor
Probe bodySS316, 2.5 mm OD
Cable15 m PUR, black
VerificationEvery finished probe

Frequently asked questions

Are your USDA probes compatible with Carrier's DataCORDER?

Our USDA probes are used on Carrier Transicold reefers. Send us the unit model and controller and we confirm the configuration and connector before production.

A probe fails calibration on a Carrier unit. Is the probe bad?

Not necessarily. The controller assumes the bath is at 0.00 °C. Check the bath with a calibrated reference thermometer first: a bath that is a few tenths of a degree off can reject a good probe or hide a bad one.

How many USDA probes does a Carrier reefer use for cold treatment?

Carrier documentation describes three USDA probes connected to the DataCORDER. The number of probes and their position in the load are set by the treatment protocol.

Need USDA probes for your Carrier fleet?

Send us the reefer model, controller, quantity and destination market. We confirm the configuration and reply with pricing.

Reference price: USD 18 per probe (15 m cable).

USDA PROBE is an independent manufacturer and is not affiliated with or endorsed by the United States Department of Agriculture, Carrier Transicold, Thermo King, Maersk Container Industry (Star Cool) or Daikin. Brand names are used only to identify equipment platforms. Product suitability should be verified for each equipment model and treatment program.