ENESFRPT

How to place USDA probes in a reefer container for cold treatment

A practical guide for reefer technicians, inspectors and exporters: container preparation, calibration, inserting probes into the fruit and placement in the load.

🌐 Español · Português · Français

Important: the number and exact position of the probes are set by each destination’s protocol or work plan, and placement is done under the supervision of the exporting country’s official agency. This guide summarizes good practice from official sources; it does not replace the protocol.

1. Prepare the container

2. Calibrate the probes

Each probe is calibrated before loading with the ice slurry method. Readings are taken until they stabilize, and each probe’s reading and correction factor are recorded on the calibration record. Step by step in our ice-bath calibration technical note.

3. How many probes

APHIS cold treatment rules require a minimum of three temperature probes or sensors per treatment enclosure, such as a container, and four for vessel holds. In reefer containers, these three probes are the ones connected to the controller’s USDA 1, USDA 2 and USDA 3 channels.

4. Where they go

ProbeUsual position
USDA 1Towards the front of the container, near the refrigeration unit
USDA 2In the middle of the load
USDA 3Towards the container doors

This front–middle–rear layout is the one used in practice. Some protocols also require a specific height, for example halfway up the stack; always follow the destination’s protocol.

5. Insert the probe into the fruit

6. Mistakes that put the treatment at risk

Need replacement probes? Our probes are compatible with Carrier, Thermo King, Star Cool and Daikin, with 15 m of cable and a 3-year warranty. Request a quotation.

Frequently asked questions

How many USDA probes does a cold treatment container use?

At least three, one per USDA channel on the controller, under APHIS rules. The destination protocol may require more.

Where does each probe go?

Usually one towards the front (near the refrigeration unit), one in the middle and one towards the doors, at the height the protocol specifies.

Do probes need calibrating before each load?

Yes. They are calibrated in an ice bath and each probe’s correction factor is recorded on the calibration record.