ENESFRPT
OEM part number · Carrier Transicold

Compatible replacement for the Carrier 12-00789-20PK4 USDA sensor

Carrier Transicold 12-00789-20PK4 is a pack of 4 NTC USDA sensors (2.5 mm, 3-pin), the Carrier reference for Asia and Oceania. Our NTC pulp probe is a compatible replacement for it, tested one by one and supplied with batch traceability.

Also compatible with 12-50089-02, 12-50089-02PK4 and 12-50089-00. See every equivalent part number in the USDA sensor cross-reference.

USDA probe with black PUR cable and stainless steel tip for Carrier Transicold reefer containers
Part number

Carrier 12-00789-20PK4 at a glance

How the OEM reference compares with the USDA PROBE equivalent. We confirm the controller, sensor setting and connector before production.

OEM referenceCarrier Transicold 12-00789-20PK4
OEM descriptionUSDA sensor, NTC 2.5 mm, 3-pin, pack of 4
RegionCarrier reference for Asia and Oceania
USDA PROBE equivalentNTC pulp probe, SS316 2.5 mm tip, 15 m PUR cable, every probe tested
Not interchangeable12-50141-00 (PT100 sensor)
Compatibility

Before you order

Three checks so the probe works on your unit from the first trip.

01

NTC sensor setting

Check that the controller's USDA sensor type is set to NTC. PT100 sensors such as Carrier 12-50141-00 use a different technology and are not interchangeable.

02

3-pin connector

Check that the unit uses a 3-pin connector for the USDA probes. We confirm the connector with you before production.

03

Ice-bath calibration

Calibrate every probe in an ice bath before the treatment, following Carrier's procedure for your controller.

Calibration

Calibrating USDA probes on Carrier units

On ML3 controllers Carrier offers an automatic calibration, in which the controller assumes the probes sit in a 0.0 °C ice bath, and an external method in which offsets between −0.3 °C and +0.3 °C are entered. On recent software a probe passes when its offset is within ±0.3 °C. Carrier's procedure calls for crushed ice made from distilled water, about 85 % ice, and a reference thermometer more accurate than the device being checked.

Always follow the calibration procedure and acceptance limits in the manufacturer's documentation for your controller and software version.

Product

Our USDA probe for Carrier

We confirm the controller, the USDA sensor setting and the connector for your Carrier units before production, so every probe arrives ready to calibrate and use.

Sensing elementNTC thermistor
Probe bodySS316, 2.5 mm OD
Cable15 m PUR, black
VerificationEvery finished probe

Frequently asked questions

Is your probe compatible with Carrier 12-00789-20PK4?

Yes. Our NTC 2.5 mm pulp probe is compatible with Carrier Transicold 12-00789-20PK4 when the controller's USDA sensor type is set to NTC and the unit uses a 3-pin connector. Send us the unit model and controller and we confirm before production.

How does 12-00789-20PK4 relate to 12-50089-02?

Both are listed by Carrier as NTC 2.5 mm, 3-pin USDA sensors. 12-00789-20PK4 is the pack-of-4 reference used for Asia and Oceania. Our probe is compatible with both.

Is your probe an original Carrier part?

No. USDA PROBE is an independent manufacturer. The Carrier part number 12-00789-20PK4 is used only to identify the sensor our probe is compatible with.

Can it be used where the unit has a Carrier 12-50141-00 sensor?

No. 12-50141-00 is a PT100 sensor. Our probe is NTC and needs the controller set to NTC.

Need USDA probes compatible with Carrier 12-00789-20PK4?

Send us the reefer model, controller, quantity and destination market. We confirm the configuration and reply with pricing.

Prices are quoted ex works (EXW). We ship to any country; shipping and customs clearance are quoted per order. 3-year warranty: any probe with a manufacturing defect is replaced free of charge.

USDA PROBE is an independent manufacturer and is not affiliated with or endorsed by the United States Department of Agriculture, Carrier Transicold, Thermo King, Maersk Container Industry (Star Cool) or Daikin. Brand names are used only to identify equipment platforms. Product suitability should be verified for each equipment model and treatment program.